VO2/VCO2: Oxymax Equal Flow
The Oxymax Equal Flow is configured for positive ventilation of multiple subjects. The total flow of a single source of air is accurately monitored before entering the equal flow distribution system. Within the equal flow distribution system is a manifold designed to distribute the incoming flow equally among all attached chambers. Up to 32 chambers are supported. A second flow meter within the instrument provides a secondary method of assuring that the total flow is properly distributed. The Oxymax Equal Flow can be supplied with positive ventilation systems that deliver 100 mL/Min to 10 LPM per subject. Consult Columbus Instruments with the specific details of your application. The Oxymax Equal Flow is constructed with stable gas sensors that have been optimized for sensing concentrations near ambient conditions. A typical Oxymax Equal Flow measurement is accurately made from readings that differ by as little as 0.1% from inlet to outlet. The Oxymax Equal Flow employs methods and control systems that assure accurate and repeatable results under changing environmental conditions. The controlling software has been designed to provide ease of use with powerful abilities that enable the Oxymax Equal Flow to adapt to your specific calorimetric measurement needs. The Oxymax Equal Flow hardware allows connection to virtually any additional testing equipment and logs their measured values into the Oxymax Equal Flow data file. Click here to obtain a copy [PDF] of the product brochure. Equations for Energy Expenditure OxyVal Oxymax Validation Unit Features / SpecificationsSimple operation with Experiment Checklist documents proper set-up and executionAuto-Tracking and Correction of errors caused by changes in the testing environment Supports 2 to 32 subjects of similar size Adaptable to a wide range of subject size and testing Oxygen Sensor: Electrochemical: Range: 18.9% to 21.2% Resolution: 0.002% O2 Drift: less than 0.25% O2 / 24 Hours Paramagnetic: Range:0-100% Resolution: 0.002% of specified range Drift: less than 0.06% of specified range per 24 Hours Carbon Dioxide Sensor: Range: 0%-0.8% Resolution: 0.002% CO2 Drift: (zero) less than 20 ppm CO2 / Hour Drift: (span) less than 20 ppm CO2 / Hour
Ordering Information7518 Oxymax Equal Flow Two Chamber System7520 Oxymax Equal Flow Four Chamber System 7540 Oxymax Equal Flow Eight Chamber System 7550 Oxymax Equal Flow Ten Chamber System 7560 Oxymax Equal Flow Sixteen Chamber System 7565 Oxymax Equal Flow Twenty Chamber System 7567 Oxymax Equal Flow Thirty Two Chamber System Contact Columbus Instruments for Custom Configurations |